Pressure transmitter high accuracy up to 0.075%
SUP-P3000 is a high performance Gauge / Absolute pressure transmitter, which is used for measuring the pressure for liquid, gas or steam flow etc, with the high accuracy up to 0.075%, P600 series is widely used in petroleum, chemical, electric power, metallurgy, water, brewing and other industrial fields.
Span/ Range Limits |
kPa |
psi |
bar |
Kgf/cm² |
|
C/S |
Span |
2~40 |
0.29~5.8 |
0.02~0.4 |
0.02~0.4 |
Range limits |
-40~40 |
-5.8~5.8 |
-0.4~0.4 |
-0.4~0.4 |
|
D |
Span |
2.5~250 |
0.3625~36.25 |
0.025~2.5 |
0.025~2.5 |
Range limits |
-100~250 |
-14.5~36.25 |
-1~2.5 |
-1~2.5 |
|
F |
Span |
30~3000 |
4.35~435 |
0.3~30 |
0.3~30 |
Range limits |
-100~3000 |
-14.5~435 |
-1~30 |
-1~30 |
|
G |
Span |
0.1~10MPa |
14.5~1450 |
1~100 |
1~100 |
Range limits |
-0.1~10MPa |
-14.5~1450 |
-1~100 |
-1~100 |
|
H |
Span |
0.21~10MPa |
30.45~3045 |
2.1~210 |
2.1~210 |
Range limits |
-0.1~21MPa |
-14.5~8000 |
-1~210 |
-1~210 |
|
I |
Span |
0.4~40MPa |
58~5800 |
4~400 |
4~400 |
Range limits |
-0.1~40MPa |
-14.5~5800 |
-1~400 |
-1~400 |
High accuracy Absolute pressure
M |
Span |
2.5~250 |
0.3625~36.25 |
0.025~2.5 |
0.025~2.5 |
Range limits |
0~250 |
0~36.25 |
0~2.5 |
0~2.5 |
|
O |
Span |
30~3000 |
-4.35~435 |
0.3~30 |
0.3~30 |
Range limits |
0~3000 |
0~435 |
0~30 |
0~30 |
PERFORMANCE SPECIFICATIONS
Reference Accuracy of Calibrated Span |
±0.075%,±0.1% (includes terminal-based linearity, hysteresis, and repeatability) If TD>10(TD=URL/SPAN), ±(0.005×TD)% |
Ambient Temperature Effects |
-20℃~65℃:±(0.075×TD+0.025)%×Span -40℃~-20℃ & 65℃~85℃:±(0.1×TD+0.025)%×Span Every 10℃ is ±0.04% ×Span (TD=1) |
Over pressure Effects |
±0.05%×Span |
Stability |
±0.1%×Span /3 years |
Power Supply Effects |
±0.001% /10V (12~36V DC) |
Output |
Two wire 4~20 mADC output with digital communications, linear or square root programmable. HART FSK protocol are superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA. |
Failure Alarm (the mode can be selected) |
Low Mode (min): 3.7 mA High Mode (max): 21 mA No Mode (hold): Keep the effective value before the fault. Note: The standard setting of failure alarm is High Mode. |
Response Time |
The amplifier damping constant is 0.1 sec; The sensor damping constant is 0.1~1.6 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time. |
UpTime |
<15s |
Ambient Temperature Limits |
-40 to 85℃ / -20 to 65℃ with LCD display or fluorine rubber sealing |
Storage and Transportation Temperature Limits |
-50 to 85℃ / -40 to 85℃ with LCD display |
Pressure Limits |
Vacuum to maximum working pressure. |
Overload Pressure Limit
Span |
40kPa |
250kPa(D/M) |
3MPa(F/O) |
|
(C) |
(S) |
|||
maximum overload pressure |
1MPa |
7MPa |
4MPa |
15MPa |
Span |
10MPa(G) |
21MPa(H) |
40MPa(I) |
|
maximum overload pressure |
20MPa |
50MPa |
50MPa |
PHYSICAL SPECIFICATIONS
Wetted Parts Materials
Isolating Diaphragm :316L stainless steel / Hastelloy C
Process Connector :316L stainless steel
Fill fluid :Silicone oil/Fluorinated oil
Amplifier Housing :Aluminum with epoxy resin coat
Process Connector Gasket :Perbunan(NBR)
Name plate and tag :304 stainless steel
Weight :1.6kg
Degrees of Protection :IP67
ตัวแทนจำหน่ายด้านการจัดจำหน่ายเครื่องมือวัด, เครื่องมือควบคุม เราเป็นตัวแทนจำหน่าย อินเวอร์เตอร์และตัวปรับสปีท ยี่ห้อต่างๆมากมาย
083-2312344 รชต(นิ้ว)
084-7522344 อรทัย(บลู)
ซอย หมู่บ้านกฤตยา ตำบล บางพลีใหญ่
อำเภอ บางพลี สมุทรปราการ 10540