Operating Principle
Following Faraday’s law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field. In the electromagnetic measuring principle, the following medium is the moving conductor. The voltage induced is proportional to the flow velocity and is supplied to the amplifier by means of two measuring electrodes. The flow volume is calculated by means of the pipe cross section area.
Application
Waster water industry: transport networks sewage treatment plants, sludges;
Chemical industry: acids alkalis, dosing applications, abrasive or corrosive mediums;
Metal & mining industry: mediums with a high solid content,like one or excavator mud;
Water industry: Revenue metering, district metering water abstraction, leakage detection;
Pulp &paper industry: pulp, pastes, sludges & other caustic mediums, liquor, additives, bleaches,colourants;
Food & beverage industry: mixing, dosing and filling of drinks under hygienic conditions filling systems applications.
Technical Data
Certification |
ISO9001:2008;CE |
Diameter |
PTFE: DN6-DN600 |
Hard rubber: DN50-DN2200 |
|
Flow Direction |
Positive; Negative |
Repeatability Error |
±0.1% |
Accuracy |
±0.5% of rate & ±1.0% of rate |
Medium Temperature |
Hard rubber liner:-20…+60°C |
High-temp rubber liner: -20…+90°C |
|
PTFE liner: -20…+120 °C |
|
High-temp PTFE liner: -20…+160°C |
|
PFA: -20...+180°C liner: -20…+160°C |
|
Nominal Working Pressure |
DN10~DN25≤4.0MPa |
DN32~DN150≤1.6MPa |
|
DN200~DN600≤1.0MPa |
|
DN700~DN22000≤0.6MPa |
|
Velocity |
0.3-10m/s |
Ambient Temperature |
-20…+60°C |
Relative Humidity |
5%~95% |
Comsumed Power |
<20W |
Model Selection
Model | LDG | Description | ||||||||||
Type | B | B Type | ||||||||||
T | T Type(DN15-DN100 only) | |||||||||||
Diameter | XXXX | DN6-DN2200 | ||||||||||
Structure | S | Compact Type with local disply | ||||||||||
L | Remote Type;10meters cable default | |||||||||||
Electrode Material | M | SS316L | ||||||||||
T | Titanium | |||||||||||
D | Tantalum | |||||||||||
H | Hastelloy Alloy C | |||||||||||
P | Platiniridium | |||||||||||
Signal Output | 0 | No Output | ||||||||||
1 | 4-20mA/Pulse | |||||||||||
Liner Material | X | Hard Rubber | ||||||||||
P | Propylene Oxide | |||||||||||
F | PTFE | |||||||||||
A | PFA | |||||||||||
Power Supply | -0 | 110-240Vac | ||||||||||
-1 | 24V DC(20-36V DC) | |||||||||||
-2 | Battery Power Supply | |||||||||||
Communication | 0 | No Communication | ||||||||||
1 | Modbus RS485 | |||||||||||
2 | HART | |||||||||||
3 | GPRS | |||||||||||
4 | Profibus DP | |||||||||||
Sensor Grounding | 0 | No Grounding | ||||||||||
1 | Grounding Ring | |||||||||||
2 | Grounding Electrode | |||||||||||
Connection | DXX | D16:DIN PN16; D25: DIN PN25;D40: DIN PN40… | ||||||||||
AXX | A15: ANSI 150#; A30: ANSI 300#; A60,A90… | |||||||||||
JXX | J10: JIS 10K; J20: JIS 20K; J40: JIS 40K… | |||||||||||
XXX | On request | |||||||||||
Body Material | CS | Carbon steel | ||||||||||
S4 | Stainless steel 304 | |||||||||||
S6 | Stainless steel 316 |