SUP-pH6.0 pH/ORP controller

Views: 8460
Applications: SUP-pH6.0 industrial pH controller is an online analyzer which applied in chemical industry metallurgy, environment protection, food, agricultrue and so on. With RS-485 can connect with computer to get data and recorder.
Types :
  • Description
  • Installation
  • Order lnformation

SUP-pH6.0 Online pH controller is a true multivariable analyzer used for measuring/controlling the pH and ORP with different temperature. The function is switchable on the device itself. Depending on the measured variable, combination electrodes (e. g. pH sensors) or split versions (glass electrodes with a separate reference electrode) can be readily connected.

Product Name Online pH controller / ORP controller
Product Brand Supmea
Measure range 0-14 (pH), ±0.02pH
-1000~1000mv (ORP), ±1mv
Resolution 0.01pH,1mv
Stability ≤0.02pH/24H,≤3mv/24H
Input Resistance ≥10~12Ω
Temperature range 0~100℃, NTC10K
Temp Compensation Manual / Auto temperature compensation
Communication RS485, standard Modbus
Signal output 4-20mA output, Maximum loop 750Ω, 0.01%FS
Power supply 220V±1%,50Hz
Relay out 250VAC, 3A

 

Wiring Method

Installation methods

Open a 92.5 * 92.5 installation hole on the instrument cabinet or installation panel. Insert the fixation screws into the hole, as shown below.

Installation of electrode 

Schematic diagram of common installation method

①Side wall installation    ②Flange mounted at the top   ③Pipe installation    ④Top installation   

⑤Submersible installation   ⑥Flow-through installation 
The interface must be in 15°oblique angle, or it will affect the normal test and use of the electrode.

 We won’t be responsible for any results due to this.     

Instrument Selection

■ Configurable isolating transmitting 4-20mA output, max.loop750Ω, 0.1%FS.

■ Conventional range controller Measuring range:

·0.01 electrode: 0.02~20.00us/cm or 0.00~20.00mΩ*cm

·0.1 electrode: 0.2~200.0us/cm

·1.0 electrode: 2~2000us/cm

·10.0 electrode: 0.02~20ms/cm

·30.0 electrode: 0.06~60ms/cm

■ Large range controller Measuring range:

·0.01 electrode: 0.2~200.0us/cm

·0.1 electrode: 2.0~2000us/cm

·1.0 electrode: 0.02~20ms/cm

·10.0 electrode: 0.2~200ms/cm

·30.0 electrode: 0.6~600ms/cm

■ Accuracy: ±1%FS Stability: ±1%FS/24H

■ Temperature measuring range:-10-130℃, accuracy: ± 0.5℃, NTC10K or PT1000 temperature offset

■ RS485 function: compactible with standard

MODBUS-RTU communication protocol

THUMUP ENGINEERING

ตัวแทนจำหน่ายด้านการจัดจำหน่ายเครื่องมือวัด, เครื่องมือควบคุม เราเป็นตัวแทนจำหน่าย อินเวอร์เตอร์และตัวปรับสปีท ยี่ห้อต่างๆมากมาย